Application of component method on partial strength connections connected by thick plate between column flanges

Traditional beam connections to the minor axis of a column have relatively low strength and stiffness. A modified detail, using a plate welded between the toes of the column flange - referred to as a toe plate connection - is examined in this paper. The results of an experimental investigation for b...

Penerangan Penuh

Disimpan dalam:
Butiran Bibliografi
Pengarang-pengarang Utama: Md. Tahir, Mahmood, Juki, Irwan, Ishak, Mohd. Yunus, Mohammad, Shahrin, Z. Awang, Abdullah
Format: Conference or Workshop Item
Diterbitkan: 2012
Subjek-subjek:
Capaian Atas Talian:http://eprints.utm.my/34352/