Long-term behaviour of LVL-concrete composite floor beams

The long-term behaviour of timber-concrete composite is characterized by the response of its three components (timber, concrete and connection) to load, moisture content, temperature and relative humidity of the environment. This paper reports results of a 4-years long-term test on three 8m span l...

Full description

Saved in:
Bibliographic Details
Main Authors: Yeoh, David, Fragiacomo, Massimo
Format: Conference or Workshop Item
Published: 2012
Subjects:
Online Access:http://eprints.uthm.edu.my/5737/
http://eprints.uthm.edu.my/5737/1/wcte2012_paper_YEOH_mas.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The long-term behaviour of timber-concrete composite is characterized by the response of its three components (timber, concrete and connection) to load, moisture content, temperature and relative humidity of the environment. This paper reports results of a 4-years long-term test on three 8m span laminated veneer lumber (LVL)- concrete composite floor beams under service load performed in an indoor, uncontrolled, and unheated environment at the University of Canterbury. The environmental conditions were characterized by either low temperature with high relative humidity or high temperature with low relative humidity, conditions considered to be reasonably severe and presumably close to service class 3 according to Eurocode 5. The mid-span deflections were extrapolated to the end of service life (50 years) and compared to span/200 deflection limit, which was exceeded by all beams.