Modelling of a 3-phase induction motor under open-phase fault using matlab/simulink

The d-q model of Induction Motors (IMs) has been effectively used as an efficient method to analyze the performance of the induction machines. This study presents a step by step Matlab/Simulink implementation of a star-connected 3-phase IM under open-phase fault (faulty 3-phase IM) using d-q model....

Full description

Saved in:
Bibliographic Details
Main Authors: Jannati, M., Sutikno, T.
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science 2016
Subjects:
Online Access:http://eprints.utm.my/71859/
http://eprints.utm.my/71859/
http://eprints.utm.my/71859/1/MohammadJannati2016_Modellingofa3PhaseInductionMotor.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The d-q model of Induction Motors (IMs) has been effectively used as an efficient method to analyze the performance of the induction machines. This study presents a step by step Matlab/Simulink implementation of a star-connected 3-phase IM under open-phase fault (faulty 3-phase IM) using d-q model. The presented technique in this paper can be simply implemented in one block and can be made available for control purposes. The simulated results provide to show the behavior of the star-connected 3-phase IM under open-phase fault condition.